Dongle Not Recognized in CodeMeter or CodeMeter Won't Start

Dongle Not Recognized in CodeMeter or CodeMeter Won't Start

Dongle Not Recognized in CodeMeter or CodeMeter Won't Start
Make sure that no unlicensed copy of other CAD/CAM systems are installed or have been installed in the past. 
Search to see if the following two files existing in the following locations. If so, please delete them from the computer.

C:\Windows\SysNative\drivers\multikey.sys

"C:\Windows\SysNative\drivers\mcamvusb.sys"

1. Make sure dongle is plugged in to the USB port.
2. If dongle is plugged in, try plugging into a different USB port
3. In Windows, in the "Type here to search" box, type: Codemeter Control Center. This should open the Codemeter Control Center. Please make sure that your dongle is showing in the Window Pane to the left, under the License tab.
4. In CodeMeter Control Center, under the Process menu, select the Stop Service selection. Once the service has been stopped then select the Restart Service selection.
5. Download and install the latest version of CodeMeter from the Wibu Systems website.
6. In the CodeMeter Control Center, select Update Firmware of Selected CmDongle.

Other issues:

Dongle not found in OPTICAM for SOLIDWORKS - hardware licensed option.
      - Worked one time.
      - Doesn't thereafter
      - Stop the service (in Services or try it in the CodeMeter Control Panel).
      - Start the service.
      - Retest.
On one customer's PC, the "WebAdmin" button didn't work on two separate browsers. It could be the port number is blocked by the firewall, but as of today, we are not sure. The webpage fails to load. The port number is - in this example - shown in red:

http://localhost/22352/container/cmcontainer_details.html?BoxSerial=2-1893620
    • Related Articles

    • USB Dongle fails to register after CodeMeter/PEPS/OPTICAM update

      If after updating the software or Codemeter to V7.4.0 you will have to follow the below instructions to fix it. The reason for the issue. "In the "wibu 740.txt" log we see "2022-01-12 11:42:19: Error updating port UMS" which has been cropping up ...
    • CodeMeter - Creating License Receipt File

      CodeMeter - Creating License Receipt File 1. Please create a Receipt file and send to OPTISOLUTIONS. If you have just installed the license then the Codemeter Control Center should still be open. If not, please reopen the Codemeter Control Center. ...
    • CodeMeter Network License Setup (Floating License)

      CodeMeter Network License Setup (Floating License) NOTE: Installation of the floating license option may require an IT specialist who is familiar with the network security on your particular network. Firewalls and other factors such as port blocking ...
    • Codemeter License Good but Program not Opening

      If you have checked and verified that the dates are correct for the license and everything else looks good you will want to check the system times on the PC and CMContainer in the CMContainer dialog. As you can see in the above picture the System ...
    • Checking your license is active/accessible

      Checking your license is active/accessible ​Symptom: Remedies: 1) Check your key (dongle) is connected to your PC. You should see it in the CodeMeter Control Panel.       - To start the Control Panel, in Windows 10, type "Code Meter Control Center" ...